Description
Specifications
Main | |
| Range | VigiPacT |
| Device short name | SA200 |
| Product or component type | Earth leakage current sensor |
| Device application | Equipment monitoring and control |
| Range compatibility | VigiPacT RH10M residual current protection relay VigiPacT RH10P residual current protection relay VigiPacT RH21M residual current protection relay VigiPacT RH21P residual current protection relay VigiPacT RH68M residual current protection relay VigiPacT RH86M residual current protection relay VigiPacT RH86P residual current protection relay VigiPacT RH99M residual current protection relay VigiPacT RH99P residual current protection relay VigiPacT RH197M residual current protection relay VigiPacT RH197P residual current protection relay VigiPacT RHU residual current protection relay VigiPacT RHUs residual current protection relay VigiPacT RMH residual current protection relay |
| current sensor type | A type closed toroid |
| [Ie] rated operational current | 400 A |
Complementary | |
| Transformer ratio | 1/1000 |
| Network type | AC/DC |
| Network frequency | 45…440 Hz |
| [Icw] rated short-time withstand current | 85 kA for 0.5 s |
| Residual short-circuit withstand current | 85 kA / 0.5 s conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 1000 V |
| Overvoltage category | IV |
| [Uimp] rated impulse withstand voltage | 12 kV |
| Mounting mode | Fixed (cables) Fixed (plain backplate) Fixed (profiled sheet metal) Fixed (slotted backplate) |
| Calorific value | 7.05 MJ |
| Connections – terminals | Screw connection 0.22 mm² |
| Diameter | 196 mm inner: |
| Cable outer diameter | 100 mm for 2 cables : 185 mm² (maximum) |
| Net weight | 1.32 kg |
| Height | 256 mm |
| Width | 274 mm |
| Depth | 46 mm |
Environment | |
| IP degree of protection | Connectors: IP20 IP30 |
| Environmental characteristic | Exposure to damp heat not in service (25…55 °C, RH 95 %) : 28 cycles conforming to IEC 60068-2-30 Salt mist: Kb/2 conforming to IEC 60068-2-52 Exposure to damp heat in service: category C2: 48 hours conforming to IEC 60068-2-56 |
| Pollution degree | Level 3 conforming to IEC 60664-1 |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -55…85 °C |
| Standards | IEC 60947-2 |
| Product certifications | CE |
Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.500 cm |
| Package 1 Width | 27.000 cm |
| Package 1 Length | 28.400 cm |
| Package 1 Weight | 1.100 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 40.000 cm |
| Package 2 Length | 60.000 cm |
| Package 2 Weight | 13.800 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 48 |
| Package 3 Height | 50.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 67.864 kg |
Contractual warranty | |
| Warranty | 18 months |





AKT 50W LED Flood/Security Light
KB32_AS Vivace 16AX 250V 2gang 2Way Switch, Aluminum Silver
E8331D20N_DG AvatarOn, switch, 20A, 250V, 2P, LED, Dark Grey
LV432642 Motor mechanism, MT 400-630, Compact NSX400/630, PowerPact Multistandard L, 380 VAC to 415 VAC 50/60 Hz
LV432598 Extended rotary handle, Compact NSX 400/630, PowerPact Multistandard L, EasyPact CVS 400/630, black standard handle, IP55
STANLEY 100Amp Fuse and Base
AKT Led Panel Light - Pop -6W
Amourd cable 4core imported 16mm
Reviews
There are no reviews yet.