LUB32 Power base, TeSys U, 3P, 32A/690V

Original price was: ₦235,890.02.Current price is: ₦224,657.16.

TeSys U standard power base, 3 poles (3NO), 32A/690V, to be completed with a control unit LUC to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a “all in one” starter controller with basic or advanced protection and control functions. It is equipped with a control terminal block, and blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

100 in stock
Add to Wishlist
Add to Wishlist
Category: Tags: , Brand:

Description

SPECIFICATION

Main

RangeTeSys
product nameTeSys Ultra
Device short nameLUB
Product or component typeNon reversing power base
Device applicationMotor control
Motor protection
Poles description3P
Suitability for isolationYes
[Ue] rated operational voltage690 V AC for power circuit
Network frequency40…60 Hz
[Ith] conventional free air thermal current32 A
[Ie] rated operational current32 A at <= 440 V
23 A at 500 V
21 A at 690 V
Utilisation categoryAC-43
AC-44
AC-41
[Ics] rated service breaking capacity50 kA at 230 V
50 kA at 440 V
10 kA at 500 V
4 kA at 690 V
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] control circuit voltage24 V AC 50/60 Hz
24 V DC
48…72 V AC 50/60 Hz
48…72 V DC
110…240 V AC 50/60 Hz
110…220 V DC

 

Complementary

Typical current consumption200 mA at 24 V DC I maximum while closing with LUCM
220 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
220 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
25 mA at 110…220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
25 mA at 110…240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
280 mA at 110…220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 110…240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 48…72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 48…72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
45 mA at 48…72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
45 mA at 48…72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
75 mA at 24 V DC I rms sealed with LUCM
80 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
90 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
Heat dissipation3 W for control circuit with LUCA, LUCB, LUCC, LUCD
1.8 W for control circuit with LUCM
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit
50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
65 ms closing with LUCM for control circuit
Mechanical durability15 Mcycles
Maximum operating rate3600 cyc/h
Product certificationsCE
UL
CSA
CCC
EAC
ASEFA
ATEX
Marine
StandardsEN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2 (pollution degree 3)
600 V conforming to UL 60947-4-1
600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2
Safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing modeClipped (DIN rail)
Screw-fixed (plate)
Connections – terminalsControl circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigid
Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigid
Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end
Tightening torqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mm
Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm
Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm
Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm
Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
Width45 mm
Height154 mm
Depth126 mm
Net weight0.9 kg
Compatibility codeLUB

 

Environment

IP degree of protectionIP20 conforming to IEC 60947-1 (front panel and wired terminals)
IP20 conforming to IEC 60947-1 (other faces)
IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for operation-25…60 °C with LUCM
-25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage-40…85 °C
Fire resistance960 °C parts supporting live components conforming to IEC 60695-2-12
650 °C conforming to IEC 60695-2-12
Operating altitude2000 m
Shock resistance10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27
4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave1 kV serial mode 24…240 V AC conforming to IEC 60947-6-2
1 kV serial mode 48…220 V DC conforming to IEC 60947-6-2
2 kV common mode 24…240 V AC conforming to IEC 60947-6-2
2 kV common mode 48…220 V DC conforming to IEC 60947-6-2
Resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3
Immunity to radioelectric fields10 V conforming to IEC 61000-4-6
Immunity to microbreaks3 ms for control circuit
Immunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11

 

Packing Units

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.500 cm
Package 1 Width13.800 cm
Package 1 Length16.900 cm
Package 1 Weight847.000 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.740 kg
Unit Type of Package 3P06
Number of Units in Package 3160
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight147.840 kg

Reviews

There are no reviews yet.

Be the first to review “LUB32 Power base, TeSys U, 3P, 32A/690V”

Your email address will not be published. Required fields are marked *

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping
Let's Chat.