Description
Specifications
Main | |
| Range | Acti9 |
| product name | Acti9 iDPN Vigi |
| Product or component type | Residual current breaker with overcurrent protection (RCBO) |
| Device short name | iDPN H Vigi |
| Device application | Distribution |
| Poles description | 1P + N |
| Number of protected poles | 1 |
| Neutral position | Left |
| [In] rated current | 32 A |
| Network type | AC |
| Network frequency | 50 Hz |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Earth-leakage sensitivity | 30 mA |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
Complementary | |
| Device location in system | Outgoer |
| [Ue] rated operational voltage | 230…240 V AC 50 Hz |
| Magnetic tripping limit | 5…10 x In |
| Residual current tripping technology | Voltage independent |
| Earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type A |
| Breaking capacity | 10000 A Icn at 230…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| [Ics] rated service breaking capacity | 7500 A 75 % x Icn at 230…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| Rated breaking and making capacity | Idm 6000 A at 230…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| Limitation class | 3 conforming to EN/IEC 61009-2-1 |
| [Ui] rated insulation voltage | 400 V AC 50 Hz |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Contact position indicator | Yes |
| control type | Toggle |
| local signalling | ON, OFF, fault trip |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| Connection pitch | 9 mm between phase and neutral |
| 9 mm pitches | 4 |
| Height | 85 mm |
| Width | 36 mm |
| Depth | 73 mm |
| Net weight | 125 g |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Locking options description | Padlocking device |
| Connections – terminals | Single terminal top or bottom 1…16 mm² rigid Single terminal top or bottom 1…10 mm² flexible Single terminal top or bottom 1…10 mm² flexible with ferrule |
| Wire stripping length | 15 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Integrated |
Environment | |
| Standards | EN/IEC 61009-2-1 |
| Product certifications | VDE |
| IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
| Pollution degree | 3 |
| Overvoltage category | III conforming to IEC 60364 |
| Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.000 cm |
| Package 1 Width | 8.200 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 225.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 54 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 12.650 kg |
Contractual warranty | |
| Warranty | 18 months |






Reviews
There are no reviews yet.